產品中心
專用產品

首頁->產品中心

產品中心

DBLS-09

產品詳情

Preface

220VAC BL drives is a powerful driver designed by Dingtuo Technology independence which is assorted with the advanced motion control industrial. The drives adopt the latest DSP specialized for motor as the core technical matched with high speed digital logic chips and high quality power module. It gets the advantage on highly integration, small volume, well protection, high reliability etc. This drives can provide: panel speed adjust command, external simulative voltage, external potentiometer, pulse width speed adjust etc.

Product Characteristic

1. System Characteristic:

Input Voltage: AC180/250VAC, 50/60Hz,

Continuous Output current: 8A, suit for less than 1500W brushless motors

Max. Output current: 15A,

Working temp.: 0~+45°C

Storage temp.:-20~+85°C

Working & storage humidity: <85% no frosting

Structure: wall-mountable box type

DimensionL180 x W100 x H210mm

2. Basic Characteristic

Cooling: Radiator

Control terminals Isolation

ProtectionOver load, over heat, over speed, over voltage, lost voltage will cause the power abnormity.

Panel6 digit LED display, 4 digit keypad operation

 

Power Terminal and Motor Terminal

No.

Terminal Name

Signal

Function

1

L1(L)(R)

Power input of main circuit

Main   circuit power input terminal AC220V 50Hz, Connect L1 and L2 while using   single phase voltage 220V

2

L2(N)(S)

3

L3(T)

4

P

High voltage DC bus line terminal

DC bus   line terminal in driver, rated power 315V

5

B1

internal   brake resistance

When using   internal brake resistance, short circuit B1 and B2, when the power is not   enough, need to use external brake resistance, break B1 and B2, connect   external brake resistance with P and B2

6

B2

external   brake resistance

7

U(MA)

Output

The motor   terminals must be connected with U,V,W one-to- one. Attention: do not reverse   the motor by exchange 3 phase terminals, it is completely different with   asynchronous motor

8

V(MB)

9

W(MC)


PE

Protection

The   release way is supplied for protection    motor and drive when current leakage

QQ圖片20170408164544.png   

     

Parameters setup

3.1 Parameters P1

This series characteristics are used to set up some functions by clients self, they can be self-adjust according to clients’ different demand. They are operation functions, have no relation with fundamental characteristics of driver

Function Name

No.

Value Range

Default Value

Function   Specification

Display   optional

P10

0~9

0

0. display real speed

1. display DC voltage of main circuit

2. display external analog input

3. display motor current

4. display internal program speed

5. U phase current

6. V phase current

7. W phase current

8. duty ratio

9 .preserve

Internal running speed

P11

0~9999

2000

When choose internal speed, the data will decide motor’s   speed(view P12)

Choose   signal sourcing  of speed

P12

0~2

1

0:internal instruct speed(tP1[0]   is internal speed, when motor running, MUP to up speed ,MDOWN to reduce speed)

1: external terminal analog   input, using SV signal of 7 pin of CN2 as motor’s speed.

2:communication order control

Direction setting

P13

0~1

0

0: CW

1: CCW

Choose   signal sourcing of start-stop

P14

0~2

1

0button by   hand controlENT is   start-stop, SET is reverse motor, +/-    is for up and reduce speed

1external   terminal control: using 4pin signal of CN2 to start and stop motor

2: communication order control

pole   pairs of motor

P15

0~99

2

attention:   pole pairs=pole/2

Driver location

P16

0~255

0

The driver location when Using communication to control motor

Speed scale factor

P17

0~99999

1520

Scale factor using for PID speed control (KP)

Speed integrating factor

P18

0~99999

320

Integrating factor using for PID speed control(KI)

Accelerated speed

P19

1~60000

6000

The parameters is directly proportional to accelerated speed, the   real accelerated speed is based on loading of motor

Decelerated speed 

P110

1~60000

6000

Rated   speed setting

P111

0~99999

3000

Speed corresponding maximum analog input (unit: RPM)

Analog input dead band

P112

0~3300

100

The function is used to set input voltage when motor speed is 0   (unit: mV)

Manual operation to adjust   speed equivalent

P113

1~999

1

Use bottom to change the speed equivalent under internal speed   type ( speed changed per press)

Recover default parameters

P114

0~1

0

Set up 1 then quit setting, connecting the power again, all   parameters will recover to default value.

3.2 Control panel operation

 QQ圖片20170408164643.jpg

 As picture on left, there are 4 keys on the panel,

 

“SET”: press this key can enter or quite P1 setup menu

 

 “▲”and “▼”: “+”and “-”,to choose the function and adjust the parameters. Otherwise, “+”is the hotkey to enter trial operation function.

 

“ENT”: “confirmation” and “operation”, when setting parameters, press this button to enter adjustment interface and jump. Under trial operation type, press ENT to start or stop motor.

 

Display instruction: total 6 digital tube shows “888888”, the light most is first and the lowest

 

Attention: The adjustment is forbidden if the adjusted value is larger than the maximum allowed, the bottom will be no response.

 

3.3 How to set parameters

 

Example:

Demand: set internal speed (P1.1) to 1000rpm/min

Operation step as below:

 

1. After connecting  with  power, display “H  0”, the driver is standby, press “SET”, will display“P0 0”
2. Press “SET”, display “P1  0”, the driver is entering P1 setting state
3.Press “▲”, until display “P1
4”
4. Press “ENT”, display “2000”, and the first of light most is flashing
5. Press “ENT”, until the flashing is moving to the fourth position
6. Press “▼”, change into “1000”
7. Press “SET”, display “P1
4”, the parameters had been set up and save automatic
8. Press “SET” again, display “P2  0”
9. Press “SET” again, back to standby state, display “H  0”, now, the new parameters adjustment had finished and take effect

Attention:
1. after adjustment, the driver need to connect with power again, then the new parameters will take effect   

     2. The parameters with “” in the list can not been adjust when motor working

3. The adjustment is forbidden if the adjusted value is larger than the maximum allowed, the bottom be will no response 

 

Wiring Diagram
QQ圖片20170408164656.png

Functions

1. Speed adjustment method

This driver provide below three adjust methods for the user to choose: 

Analog voltage adjustment speed: the terminals of external potentiometer connect to the +5v terminal in signal control and COM, connect the regulator terminal to SV, not only make it possible to adjust speed by external potentiometer (10K~100K), but also can achieve speed adjust through other control unit (Such as PLC, Microcontroller, etc) input analog voltage to SV. The acceptance of SV is DC 0V~+5V, and the corresponding motor rotate speed is 0 to rated speed.

You also can use external digital signal to adjust speed: apply PWM with 5V amplitude and 1KHz~2KHz Frequency between SV and GND to adjust the speed. The motor rotate speed will adjust by the duty radio liner adjustment.

The third method to adjust speed is using communication order controlling

2. Motor operate/stop control (EN)
You can control the brushless motor to run or stop by controlling the terminal “EN” and “COM” connecting. The motor will run when we connect the terminal “EN” to “COM”; when shut down, the motor will stop naturally. And the starting time will decided by the initial setup in panel, the motor running will be affected by load added 

3. Motor rotation direction control ( F/R )
You can control the motor rotation direction by controlling the terminal “F/R” and “COM” connecting. When connect terminal “F/R” to terminal “COM”, the motor will run at CCW (view from motor output side), and when shut down, the motor will run at another direction.

Attention: If you need to change the motor rotation direction, please stop the motor at first, otherwise the controller shall be caused to damage.

4. Break the motor to stop  ( BK )
You can break the motor to stop if need. Motor can be running when the terminal “BK” not connect to “COM”, but if you connect these two terminal together, motor will stop quickly. If the overload alarm frequently, you need to add brake resistance for driver, the resistance value is not less than 100Ω, and power is not less than 100W. Attention: when install the brake resistance, the driver must be under without power and indicating light state. The brake resistance accessories is for charge

5. Speed signal output (PG) 

The speed pulse output is 0C, output 30V/10mA max. You can connect with a resistance (3K ohm ~10K ohm) between PG and the input power to get the speed pulse signal. The relationship of output frequency F(Hz) and speed N(rpm)is: F=N * P / 60 , P is the pole pairs of motor, Output Pulse per revolution.

6. Alarm output (ALM)
The alarm output port is 0C, output 30V/10mA max. You can connect with a resistance (3K ohm ~10K ohm) between ALARM output and the input power to get the alarm signal. When alarm, this port and the GND connecting (Low voltage), and the controller will stop working and keep in alarm status.

Working methods

The driver has three working methods by setting panel. The first is panel manual operation, press R/S to start or stop the motor, press + - to up or reduce the speed, press∣”ENTER to confirm the speed. The second is by external terminals, the motor is working with settle, digital tube display running speed. The third method is communication type.

Protection type

When the motor is running abnormally, the digital tube will display:

(1) OL   motor locked

(2) OC   over current

(3) HE   hall signal failure

(4) LV   under voltage input

(5) HU   over voltage input

(6) EE   IPM failure protection

(7) OT   motor too hot

 

System using

Firstly, connect motor and driver lines (wounding lines, hall signal lines and power line) in strictly observe related norms and specification. It can’t to reverse the motor by change lines connection, it is completely different with asynchronous motor. The motor and driver can not work normally even damaged if lines connected wrong

You can start the trial operation after connecting motor power line, hall line and driver power lines. At first, set the control panel or terminal control, secondly set the pole pairs of brushless DC motor (wrong pole pairs will display inaccurate speed and offer wrong inner parameter ), then press the start button, enlarge the potentiometer slightly , the motor will run, if the motor do not work, or shake, or alarm, maybe the lines connection is not correct, or load is too large, please check again, until the motor running normally.

 

上一個:
下一個:
?

2006-2024 深圳市鼎拓達機電有限公司版權所有 粵ICP備05142847號 技術支持:神州通達網絡

深圳總公司:

電話:0755-25796858 

傳真:0755-25796696 

郵箱:sales@www.hljcljy.net 

地址:廣東省深圳市南山區西麗街道麻磡社區麻磡路18號工業區8棟5樓




華中辦事處:童仁青  18975332020 

地址:湖南省長沙縣星沙大道39號財富港灣1棟2單元1613號

華東辦事處:朱興科 18128820282  

地址:江蘇省蘇州市昆山市昆山開發區四季華城32棟2單元1503

 
微信掃一掃   手機掃一掃
在線客服
亚洲AV无码精品国产成人| 97精品人妻一区二区三区香蕉| 免费看高清大片的APP在线看| 97人人添人澡人人爽超碰| 无码一区18禁3D| 女人丝不挂的正面裸体| 国产香蕉97碰碰视频VA碰碰看 | 黑人上司好猛我好爽中文字幕| となりの家のネツト在线| 亚洲精品无码正在夜夜骚| 色既是空在线观看| 好黄好污美女裸体网站| 中国高清WINDOWS视频软件| 无码囯产精品一区二区免费| 男男GV白嫩小受GV在线播放| 国产免费又爽又色又粗视频| BT天堂新版中文在线地址| 亚洲国产午夜无码精品小说| 日韩无码视频专区| 国内精品视频一区二区三区| S货叫大点声C烂你的SB视频| 亚洲成A人片77777kkkk| 欧美激情一区蜜桃传媒| 黑人巨茎迎战白嫩少妇| 成人欧美一区二区三区黑人免| 艳妇乳肉豪妇荡乳在线观看| 偷拍精品视频一区二区三区| 欧美成人国产精品视频| 国产精品JK白丝AV网站| 野花おっさんとわたし| 婷婷色综合AⅤ视频| 男同GAY片自慰AV网站| 国内精品乱码卡一卡2卡三卡| 宝贝把腿张得大一点就不痛了 | 在火车和后妈妈谁在一起是什么书| 无码精品A∨在线观看| 欧美激情精品久久久久久| 精品人伦一区二区三区蜜桃| 丰满妇女强高潮18ⅩXXXHD| 最新永久无码AV网址亚洲| 亚洲VA在线∨A天堂VA欧美V| 三上悠亚AV影院在线看| 美女裸体无遮挡永久免费视频AP | 色欲色香天天天综合无码WWW| 国产大陆亚洲精品国产| 欧美日韩一区二区三区自拍 | 久久国国产免费999| 国产成人精品亚洲日本专区61 | 亚洲已满18点击进入在线看片| 脱了老师内裤猛烈进入的软件| 欧美熟妇呻吟猛交XX性| 久久久久精品无码一区二区三区| 草草影院CCYYCOM| 亚洲国产成人精品无码区在线播放| 日韩人妻无码一区二区三区综合部| 巨大黑人极品videos精品| 国产在线看片无码人精品| 丁香花在线观看视频在线| 97久久精品无码一区二区| 亚洲色18禁成人网站WWW永久| 无套内射无矿码免费看黄| 日本高清在线观看视频WWW色 | 妺妺窝人体色www人体| 极品国产主播粉嫩在线| 国产SUV精品一区二区883| JEΑL0USVUE成熟50M| 永久看一二三四线| 亚洲国产精品久久久久久| 无码成人AⅤ免费中文字幕| 人与物VIDEOS另类XXXX| 免费A级毛片无码A∨中文字幕下| 精品国产乱码久久久久久软件大全| 国产成人精品午夜福利| 宝宝腿趴开一点就不会疼的原因| 中文字幕AV无码一区电影DVD | 前夫6天要了我25次| 老熟女太熟了95AV| 精品国产一区二区三区国产区| 国产精品YY9299在线观看| 成人3D动漫一区二区三区| 92午夜少妇极品福利无码电影| 亚洲熟妇无码av叧娄本色| 亚洲AV成人无码久久精品老人| 深入浅出TXL金银花讲的什么| 人妻丰满AV无码中文字幕| 免费看国产曰批40分钟| 久久国产热精品波多野结衣AV| 国产一区二区波多野结衣| 国产成 人 在线观看 亚洲| 被医生吃奶吃高潮了H| 99国精产品灬源码1688钻石| 一区二区无码免费视频| 亚洲国产成人无码AV在线影院L| 无码少妇一区二区浪潮av| 色欲人妻AAAAAA无码| 人妻少妇精品无码专区漫画| 逆徒每天都想着欺师犯上| 久久夜色精品国产网站| 精品无人区一区二区三区的特点 | 人妻少妇久久中文字幕一区二区| 免费无码一区二区三区蜜桃大| 久久久精品久久久久久96| 黑人玩弄人妻1区二区| 国产无遮挡无码视频免费软件| 国产成人无码精品一区不卡| 成熟人妻AV无码专区| WWW.一本色道88久久爱| 99RE6热这里只精品首页| 在线观看的AV网站| 亚洲中字幕日产2021草莓| 亚洲乱码日产精品BD在线观看| 亚洲AV无码乱码在线观看牲色| 无码激情亚洲一区| 少妇夜夜春夜夜爽试看视频| 日本国产一区二区三区在线观看| 欧美日韩一区二区成人午夜电影| 免费人妻精品一区二区三区| 老熟仑妇乱一区二区AV| 久久精品中文字幕无码| 精品无码国产一区二区三区麻豆| 国产在线孕妇孕交| 国产日产欧产精品精品APP| 国产精品电影久久久久电影网| 国产 麻豆 日韩 欧美 久久| 东北浪妇王梅娟偷人视频| 宝宝握住坐下~它会自己动 | 成人午夜亚洲精品无码网站 | 国产成人无码18禁午夜福利网址 | 宝贝把腿开大让我添添电影 | 44分钟欧美人与禽交片MP4| 真人新婚之夜破苞第一次视频| 夜夜添无码一区二区三区| 亚洲人成伊人成综合网久久久| 亚洲国产成人综合精品| 亚洲AV综合AV成人网在线观看| 亚洲AV成人中文无码专区| 性生大片免费观看性| 小S货又想挨C了叫大声点| 午夜不卡久久精品无码免费| 无人区码一码二码三码区别图片| 玩两个丰满老熟女久久网| 婷婷成人综合激情在线视频播放 | 久久久精品波多野结衣| 久久成人A毛片免费观看网站| 精品人妻无码一区二区色欲AⅤ| 后Λ式动态后Λ式动态图AV| 狠狠噜天天噜日日噜视频麻豆| 好吊色欧美一区二区三区四区| 狠狠噜天天噜日日噜视频麻豆 | 日日天干夜夜狠狠爱| 日韩一区二区三区精品视频| 日韩一区二区三区在线| 色妞WW精品视频7777| 色欲蜜臀av无码久久浪潮一区| 日韩A级成人免费无码视频| 日韩欧美国产精品亚洲二区| 三级 丰满 人妻 少妇| 少妇开裆肉丝自慰流白浆| 视频一区二区三区免费| 天美传媒MV在线看免费下载安装| 婷婷五月花丁香综合| 无码人妻一区二区中文| 小雪的L3又嫩又紧又多水图| 亚洲AV日韩AV高潮喷潮无码| 亚洲成人AV免费| 亚洲色大成网站WWW永久| 夜夜添无码一区二区三区| 真实的国产乱ⅩXXX66小说| 18禁纯肉高黄无码动漫| 1000部又爽又黄无遮挡的视频| AAAAA级少妇高潮大片免费看| XXⅩ鲁交自慰免费看| 成年女人A级毛片免费观看 | 啊~CAO死你个小SAO货视频| 超碰人人爽天天爽天天做| 丰满人妻熟妇乱又伦精品视| 国产极品熟女沙发内射AV| 国产特级毛片AAAAAA高清| 黑人GAY大长雕TUBE| 精产国品一二三产区区别在哪儿| 久久国产成人精品国产成人亚洲| 久久久久亚洲精品无码网址| 和朋友换娶妻一起换着高清| 精品国产一区二区三区国产区 | ZOOMSERVO兽狗产品优势| 成人国产一区二区三区精品不卡| 都市 亚洲 自拍 小说 校园| 国产成人无码精品久久久露脸| 国产欧美精品一区二区三区四区 | 亚洲MV国产MV在线MV综合试| 亚洲色大成网站WWW在线观看| 影音先锋人妻啪啪AV资源网站| 中文字幕丰满伦子无码| 一边做饭一边暴躁怎么办 | NARUTOMANGA全彩纲手| 成AV人电影在线观看| 国产成人精品白浆久久69| 国产无遮挡又黄又爽免费视频 | 一本到无码AV专区无码不卡| 中国在线观看免费国语版|